ME Command

ME, <no>,<nfirst>,<nlast>, <xc>,<yc>,<zc>

defines the following multiple excitation options for ACS SASSI HOUSE module:

  • <no> - number of input motion (between 1 and 10)
  • <nfirst> - first foundation node for input motion <no>
  • <nlast> - last foundation node for input motion <no>
  • <xc> - x-coordinate of control point for input motion <no>
  • <yc> - y-coordinate of control point for input motion <no>
  • <zc> - z-coordinate of control point for input motion <no>

Note: This instruction is provided for input files. To set the multiple excitation analysis options for the ACS SASSI HOUSE module from the ACS SASSI PREP or Submodeler, use the Options / Analysis menu option.