HOUSE Command

HOUSE,<gravity>,<gelev>,<opmode>,<dim>,<imp>,<coh>,<wpass>, <me>,<cmplxspec>

defines the following analysis options for ACS SASSI HOUSE module:

  • <gravity> - acceleration of gravity
  • <gelev> - ground elevation
  • <opmode>- operation mode
    • 0 - complete solution
    • 1 - data check only
  • <dim>- analysis dimension
    • 0 - 1D
    • 1 - 2D
    • 2 - 3D
  • <imp>- method of computing impedance matrix
    • 0 - direct flexible volume method
    • 1 - skin flexible volume method
  • <coh>- soil motion
    • 0 - coherent
    • 1 - incoherent
  • <wpass> - wave passage
    • 0 - disable
    • 1 - enable
  • <me> - multiple excitation
    • 0 - disable
    • 1 - enable
  • <cmplxspec> - complex spectral amplification ratio
    • 0 - disable
    • 1 - enable

Note: This instruction is provided for input files. To set the analysis options for the ACS SASSI HOUSE module from the ACS SASSI PREP or SASSI User Interface, use the Options / Analysis menu option.