ANALYS,<opmode>,<type>,<mode>,<save>,<prnt>,<fopt>,<ang>,<xc>,
<yc>,<zc>,<impe>,[simul],[ffr]
defines the following analysis options for ACS SASSI ANALYS module:
opmode - operation mode
0 - complete solution
1 - data check only
type - analysis type
0 - seismic
1 - foundation vibration
mode - analysis mode
save - file save option
prnt - print option for transfer functions
fopt - frequency option
ang - coordinate transformation angle
xc - x-coordinate of control point
yc - y-coordinate of control point
zc - z-coordinate of control point
impe - calculation mode for the global impedances of the foundation
simul - number of simultaneous cases to be simulated. (default = 0)
ffr - Free Field Randomization
0 - Load (default)
1 - Motion
Note: This instruction is provided for input files. To set the analysis options for the ACS SASSI ANALYS module from the ACS SASSI PREP and ACS-SASSI User Interface, use the Options / Analysis command.